University of LiègeULgFaculty of EngineeringFacSALibrary News   
Jean-Michel Redouté - Publications ORBI
Heydari, F., Ebrahim, M. P., Redouté, J.-M., Joe, K., Walker, K., & Rasit Yuce, M. (2020). A chest-based continuous cuffless blood pressure method: Estimation and evaluation using multiple body sensors. Information Fusion, 54, 119-127.
Peer reviewed (verified by ORBi)
Blood pressure (BP) is a critical vital sign in health, measured millions of times per day worldwide. Current BP measurement requires cumbersome tools, is painful and can be inconvenient. Non-invasive cuffless ...
Al Mamun, M. A., Vera Anaya, D., Wu, F., Redouté, J.-M., & Yuce, M. R. (2019). Radio map building with IEEE 802.15.4 for indoor localization applications. Proceedings (pp. 181-186). Institute of Electrical and Electronics Engineers Inc.
Peer reviewed
Automated radio map building for Radio Signal Strength (RSS) based fingerprinting localization is implemented in this paper. Fingerprinting technique is composed of an offline phase for collecting geotagged ...
Daneshvar, S. H., Maymandi-Nejad, M., Sachdev, M., & Redouté, J.-M. (2019). A Charge-Depletion Study of an Electrostatic Generator with Adjustable Output Voltage. IEEE Sensors Journal, 19(3), 1028-1039.
Peer reviewed (verified by ORBi)
Micro-scale generators are becoming more popular for harvesting energy to power bio-implantable devices and sensor networks. Most electrostatic generators (ESGs) use constant capacitors as storage or reservoir ...
Daneshvar, S. H., Maymandi-Nejad, M., Yuce, M. R., & Redouté, J.-M. (2019). A performance comparison between synchronous and asynchronous electrostatic harvesters. Proceedings (pp. 349-354). Institute of Electrical and Electronics Engineers Inc.
Peer reviewed
Synchronous electrostatic harvesters are able to deliver a higher amount of power to electronic devices compared to the asynchronous electrostatic harvesters. However, synchronous generators need a control ...
Morrison, D., Delic, D., Yuce, M. R., & Redouté, J.-M. (2019). Multistage Linear Feedback Shift Register Counters with Reduced Decoding Logic in 130-nm CMOS for Large-Scale Array Applications. IEEE Transactions on Very Large Scale Integration (VLSI) Systems, 27(1), 103-115.
Peer reviewed (verified by ORBi)
Linear-feedback shift register (LFSR) counters have been shown to be well suited to applications requiring large arrays of counters and can improve the area and performance compared with conventional binary ...
Aldaoud, A., Redouté, J.-M., Ganesan, K., Rind, G. S., John, S. E., Ronayne, S. M., Opie, N. L., Garrett, D. J., & Prawer, S. (2018). Near-field wireless power transfer to stent-based biomedical implants. IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 2(3), 193-200.
Peer reviewed
Safe wireless power transfer is an essential requirement for biomedical implants. Emerging technologies are becoming smaller, less invasive, and consume less power. Moreover, stent-based devices are being ...
Aldaoud, A., Soto-Breceda, A., Tong, W., Conductier, G., Tonta, M. A., Coleman, H. A., Parkington, H. C., Clarke, I., Redouté, J.-M., Garrett, D. J., & Prawer, S. (2018). Wireless multichannel optogenetic stimulators enabled by narrow bandwidth resonant tank circuits. Sensors and Actuators, A: Physical, 271, 201-211.
Peer reviewed (verified by ORBi)
Optogenetic neuromodulation is a powerful technique used to study cells that form part of neuronal circuits. Light stimulation of neurons has led to a deeper understanding of autism, schizophrenia and ...
Alsunaydih, F. N., Redouté, J.-M., & Yuce, M. R. (2018). A Locomotion Control Platform with Dynamic Electromagnetic Field for Active Capsule Endoscopy. IEEE Journal of Translational Engineering in Health and Medicine, 6.
Peer reviewed (verified by ORBi)
Conventional radiological and endoscopic techniques utilizing long tubes were ineffective in visualizing the small bowel mucosa until the development of wireless capsule endoscopy (WCE). WCE is a revolutionary ...
Anjan Kumar Pudi, N. S., Redouté, J.-M., & Baghini, M. S. (2018). A Generic EMI-Immune Technique for Differential Amplifiers With Single-Ended Output. IEEE Transactions on Electromagnetic Compatibility, 60(4), 958-964.
Peer reviewed (verified by ORBi)
This paper presents a unique methodology to calculate the filtering capacitances of the OpAmp already reported in the literature. The methodology aims to show that there is an optimal solution that can be used ...
Arefin, M. S., Redouté, J.-M., & Yuce, M. R. (2018). Integration of Low-Power ASIC and MEMS Sensors for Monitoring Gastrointestinal Tract Using a Wireless Capsule System. IEEE Journal of Biomedical and Health Informatics, 22(1), 87-97.
Peer reviewed (verified by ORBi)
This paper presents a wireless capsule microsystem to detect and monitor the pH, pressure, and temperature of the gastrointestinal tract in real time. This research contributes to the integration of sensors ...
Bhatt, D., Mukherjee, J., & Redouté, J.-M. (2018). Low-power switched transconductance mixer and LNA design for Wi-Fi and WiMAX applications in 65 nm CMOS. IET Microwaves, Antennas and Propagation, 12(10), 1736-1744.
Peer reviewed (verified by ORBi)
This study proposes a wide-band low-power low-noise amplifier (LNA) and switched transconductance (SwGm) mixer. The proposed mixer is realised with a fully differential complementary metal oxide semiconductor ...
Buxi, D., Hermeling, E., Mercuri, M., Beutel, F., Van Der Westen, R. G., Torfs, T., Redouté, J.-M., & Yuce, M. R. (2018). Systolic Time Interval Estimation Using Continuous Wave Radar with On-Body Antennas. IEEE Journal of Biomedical and Health Informatics, 22(1), 129-139.
Peer reviewed (verified by ORBi)
The estimation of systolic time intervals (STIs) is done using continuous wave (CW) radar at 2.45 GHz with an on-body antenna. Motivation: In the state of the art, typically bioimpedance, heart sounds and/or ...
Daneshvar, S. H., Maymandi-Nejad, M., Yuce, M. R., & Redouté, J.-M. (2018). Power Efficient Optimization Procedure for Asynchronous Electrostatic Generators. Proceedings (pp. 297-300). Institute of Electrical and Electronics Engineers Inc.
Peer reviewed
Asynchronous electrostatic generators have the advantage of omitting the control circuit used for synchronizing mechanical movements with electrical switching events, which results in simplified implementation ...
Ebrahim, M. P., Heydari, F., Redouté, J.-M., & Yuce, M. R. (2018). Accurate Heart Rate Detection from On-Body Continuous Wave Radar Sensors Using Wavelet Transform. Proceedings of IEEE Sensors, 2018-October.
Peer reviewed (verified by ORBi)
On-Body Continuous Wave Radar (CWR) systems can be used to monitor cardiac activities. This paper presents a signal processing method based on the wavelet transform to remove the noise components of the time ...
Hevdari, F., Ebrahim, M. P., Wu, T., Walker, K., Joe, K., Redouté, J.-M., & Yuce, M. R. (2018). Continuous cuffless blood pressure measurement using body sensors. Proceedings of IEEE Sensors, 2018-January.
Peer reviewed (verified by ORBi)
Non-invasive cuffless blood pressure (BP) measurement using pulse arrival time (PAT) offers some unique features for healthcare applications including improved wearability and user-friendly BP monitoring ...
Kennedy, S., Yuce, M. R., & Redouté, J.-M. (2018). Fully Integrated Switched-Capacitor DC/DC Converters With Clock Slope EMI Control. IEEE Transactions on Electromagnetic Compatibility.
Peer reviewed (verified by ORBi)
This correspondence discusses the implementation of clock slope control to reduce emissions from fully-integrated step-up dc/dc converters. The addition of clock slope control is a common technique used to ...
Kennedy, S., Yuce, M. R., & Redouté, J.-M. (2018). A low-EMI fully integrated switched-capacitor DC/DC converter. IEEE Transactions on Electromagnetic Compatibility, 60(1), 225-233.
Peer reviewed (verified by ORBi)
This paper presents a novel fully integrated step-up dc/dc converter containing circuits to improve electromagnetic emissions. This design utilizes current sources to limit the impulsive current flow into the ...
Kennedy, S., Yuce, M. R., & Redouté, J.-M. (2018). Susceptibility of flash ADCs to electromagnetic interference. Microelectronics Reliability, 81, 218-225.
Peer reviewed (verified by ORBi)
Integrated devices acquiring environmental, industrial or biomedical signals are ubiquitous and require sensor systems to be situated in electromagnetically hostile environments and continue to operate ...
Morrison, D., Kennedy, S., Delic, D., Yuce, M., & Redouté, J.-M. (2018). A Triple Integration Timing Scheme for SPAD Time of Flight Imaging Sensors in 130 nm CMOS. Proceedings (pp. 13-16). Institute of Electrical and Electronics Engineers Inc.
Peer reviewed
This paper presents a triple integration time-to-amplitude conversion (TAC) scheme for high resolution SPAD time of flight cameras. Two reference integrators are added to the conventional integration based TAC ...
Pudi, N. S. A. K., Boyapati, S., Redouté, J.-M., & Baghini, M. S. (2018). Analytical and Experimental Validation of Robustness of the Current Mirrors to EMI. IEEE Transactions on Electromagnetic Compatibility.
Peer reviewed (verified by ORBi)
This paper presents two electromagnetic interference (EMI) resisting current mirror topologies that use a linearization technique to filter out the EMI without producing any offset at the output. A proposed ...
Qiu, C., Wu, T., Heydari, F., Redouté, J.-M., & Yuce, M. R. (2018). Wearable Blood Pressure Monitoring Based on Bio-Impedance and Photoplethysmography Sensors on the Arm. Proceedings of IEEE Sensors, 2018-October.
Peer reviewed (verified by ORBi)
In this paper, a wearable beat-to-beat blood pressure (BP) monitoring system using the pulse transit time (PTT), based on the bio-impedance (BI) and photoplethysmography (PPG) sensors is proposed. PTT is ...
Wu, F., Redouté, J.-M., & Yuce, M. R. (2018). A Self-Powered Wearable Body Sensor Network System for Safety Applications. Proceedings of IEEE Sensors, 2018-October.
Peer reviewed (verified by ORBi)
Monitoring of environmental conditions has become increasingly crucial because poor environments can lead to severe health issues. This paper presents a self-powered wearable sensor network for safety ...
Wu, F., Redouté, J.-M., & Yuce, M. R. (2018). WE-safe: A self-powered wearable IoT sensor network for safety applications based on lora. IEEE Access, 6, 40846-40853.
Peer reviewed (verified by ORBi)
Poor environmental conditions can lead to severe health problems. It is essential to develop effective, reliable, and fast response systems for people working in hazardous environments. This paper presents a ...
Wu, F., Rudiger, C., Redouté, J.-M., & Yuce, M. R. (2018). Live Demonstration: An IoT Platform for Environmental Monitoring Using Self-Powered Sensors. Proceedings of IEEE Sensors, 2018-October.
Peer reviewed (verified by ORBi)
Monitoring of environmental conditions has become increasingly crucial because poor environments can lead to severe health issues [1]. A wireless sensor network (WSN) is a promising solution to collect useful ...
Wu, F., Rudiger, C., Redouté, J.-M., & Yuce, M. R. (2018). WE-Safe: A wearable IoT sensor node for safety applications via LoRa. IEEE World Forum on Internet of Things, WF-IoT 2018 - Proceedings (pp. 144-148). Institute of Electrical and Electronics Engineers Inc.
Peer reviewed
This paper presents a wearable Internet of Things (IoT) sensor node aimed at monitoring harmful environmental conditions for safety applications via LoRa wireless technology. The proposed sensor node is low ...
Wu, T., Redouté, J.-M., & Yuce, M. R. (2018). Live Demonstration: A Wearable Wireless Medical Sensor Network System Towards Internet-of-Patients. Proceedings of IEEE Sensors, 2018-October.
Peer reviewed (verified by ORBi)
The modern healthcare industry is emerging with the technology of Internet of Things (IoT) [1]. In our paper submitted to IEEE Sensors 2018 [2], we propose and demonstrate a wearable wireless medical sensor ...
Wu, T., Redouté, J.-M., & Yuce, M. R. (2018). A Wearable Wireless Medical Sensor Network System Towards Internet-of-Patients. Proceedings of IEEE Sensors, 2018-October.
Peer reviewed (verified by ORBi)
This paper presents a wireless, medical network system for vital signs monitoring with a low-power wearable sensor node. The proposed implementation consists of a master sensor board, a sensor node and a ...
Wu, T., Redouté, J.-M., & Yuce, M. R. (2018). A Wireless Implantable Sensor Design With Subcutaneous Energy Harvesting for Long-Term IoT Healthcare Applications. IEEE Access, 6, 35801-35808.
Peer reviewed (verified by ORBi)
In this paper, a wireless implantable sensor prototype with subcutaneous solar energy harvesting is proposed. To evaluate the performance of a flexible solar panel under skin, ex-vivo experiments are conducted ...
Alsunaydih, F. N., Redouté, J.-M., & Yuce, M. R. (2017). A wireless capsule endoscopy steering mechanism using magnetic field platform. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 3036-3039.
Peer reviewed
In this paper, a new steering mechanism for wireless capsule devices is presented. The proposed system consists of a platform generating a magnetic field to direct and control the motion of a capsule. The ...
Arefin, M. S., Redouté, J.-M., & Yuce, M. R. (2017). Wireless biosensors for POC medical applications. Medical Biosensors for Point of Care (POC) Applications (pp. 151-180). Elsevier Inc.
Peer reviewed
Biosensors transform physiological or biological information into electrical measurements using electronic circuits. The detected information is transmitted remotely to a data acquisition platform or a server ...
Bhatt, D., Mukherjee, J., & Redouté, J.-M. (2017). A 1–11 GHz ultra-wideband LNA using M-derived inductive peaking circuit in UMC 65 nm CMOS. Microwave and Optical Technology Letters, 59(3), 521-526.
Peer reviewed (verified by ORBi)
A high-gain, low-power, and low-noise amplifier (LNA) is designed in UMC 65 nm radio frequency (RF)-CMOS technology for operation over the 1 to 11 GHz RF band. This LNA design is based on an m-derived ...
Bhatt, D., Mukherjee, J., & Redouté, J.-M. (2017). A Self-Biased Mixer in μm CMOS for an Ultra-Wideband Receiver. IEEE Transactions on Microwave Theory and Techniques, 65(4), 1294-1302.
Peer reviewed (verified by ORBi)
A self-biased CMOS analog mixer for ultra-wideband (UWB) applications is presented in this paper. The proposed mixer is complementary and self-biased, and has lower power consumption, superior isolation, and ...
Boyapati, S., Redouté, J.-M., & Baghini, M. S. (2017). Modeling and design of an EMI-immune source-buffered miller OpAmp in 0.18 μm CMOS technology. 2017 International Symposium on Electromagnetic Compatibility - EMC EUROPE 2017, EMC Europe 2017.
Peer reviewed
This paper presents the modeling and design of a source-buffered Miller operational amplifier structure that is highly immune to electromagnetic interference (EMI). The source-buffered Miller operational ...
Boyapati, S., Redouté, J.-M., & Baghini, M. S. (2017). A robust CMOS Miller OpAmp with High EMI-immunity. 2017 International Symposium on Electromagnetic Compatibility - EMC EUROPE 2017, EMC Europe 2017.
Peer reviewed
This paper presents a robust CMOS Miller operational amplifier (OpAmp) that has high immunity to electromagnetic interference (EMI). The proposed robust CMOS Miller operational amplifier uses the modified ...
Boyapati, S., Redouté, J.-M., & Shojaei Baghini, M. (2017). Design of A Novel Highly EMI-Immune CMOS Miller OpAmp Considering Channel Length Modulation. IEEE Transactions on Circuits and Systems I: Regular Papers, 64(10), 2679-2690.
Peer reviewed (verified by ORBi)
This paper presents a novel CMOS Miller operational amplifier (OpAmp) that has high immunity to electromagnetic interference (EMI). The proposed CMOS Miller OpAmp uses the replica concept with the source ...
Buxi, D., Dugar, R., Redouté, J.-M., & Yuce, M. R. (2017). Comparison of the impedance cardiogram with continuous wave radar using body-contact antennas. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 693-696.
Peer reviewed
This paper describes a continuous wave (CW) radar system with body-contact antennas and basic signal processing. The goal is to assess the signals' reproducibility across different subjects as well as a ...
Buxi, D., Redouté, J.-M., & Yuce, M. R. (2017). Systolic time interval estimation at the sternum using continuous wave radar with body-contact antennas. 2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks, BSN 2017, 87-90.
Peer reviewed
Cardiovascular vital signs are measured using continuous wave (CW) radar at 2.45GHz with a body-contact antenna. Using a previously collected database of thirty second recordings at paced breathing conditions ...
Hamid, R., Wijesundara, S., McMillan, L., Scott, D., Redouté, J.-M., Ebeling, P. R., & Yuce, M. R. (2017). Development of a wearable plantar force measurement device for gait analysis in remote conditions. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 139-142.
Peer reviewed
The pressure field that exists between the foot and the supporting surface is identified as the foot plantar pressure. The information obtained from foot plantar pressure measurements has useful applications ...
Kennedy, S., Yuce, M. R., & Redouté, J.-M. (2017). Evaluation of conducted emission test methods for charge pump DC/DC converters. IEEE Transactions on Reliability, 66(1), 170-177.
Peer reviewed (verified by ORBi)
This paper presents conducted emission measurements for a group of commercially available capacitive step-up dc/dc converters. A comparison of the traditional line impedance stabilization network conducted ...
Laurenson, C., Yuce, M. R., & Redouté, J.-M. (2017). A sub 125 nW sub-threshold analog adaptive sampler in 180 nm CMOS. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 722-725.
Peer reviewed
We present an ultra low power analogue adaptive sampler for extraction of features from an arterial blood pressure signal, prior to ADC operation or conversion. The architecture is implemented and simulated in ...
Matig-A, G. E., Yuce, M. R., & Redouté, J.-M. (2017). Design of a CML Transceiver with Self-Immunity to EMI in 0.18-μ m CMOS. IEEE Transactions on Circuits and Systems I: Regular Papers, 64(4), 981-991.
Peer reviewed (verified by ORBi)
This paper presents the design of an integrated current mode logic (CML) transceiver system that demonstrates a superior robustness to electromagnetic interference (EMI). The effect of EMI on a typical CML ...
Matig-A, G. E., Yuce, M. R., & Redouté, J.-M. (2017). Design of an EMI self-immune VML transmitter in 0.18-μ m CMOS. IEEE Transactions on Electromagnetic Compatibility, 59(5), 1646-1649.
Peer reviewed (verified by ORBi)
This letter discusses an integrated voltage-mode logic (VML) transmitter demonstrating a superior self-immunity to electromagnetic interference (EMI). Both the proposed and typical transmitters were fabricated ...
Richelli, A., Colalongo, L., Toninelli, L., Rusu, I., & Redouté, J.-M. (2017). Measurements of EMI susceptibility of precision voltage references. Proceedings of the 2017 11th International Workshop on the Electromagnetic Compatibility of Integrated Circuits, EMCCompo 2017, 162-167.
Peer reviewed
This paper investigates and reports on the susceptibility of commercial voltage references to electromagnetic interference (EMI). Two separate scenarios have been considered. In the first experiment, the ...
Richelli, A., Kennedy, S., & Redouté, J.-M. (2017). An EMI-Resistant Common-Mode Cancelation Differential Input Stage in UMC 180 nm CMOS. IEEE Transactions on Electromagnetic Compatibility, 59(6), 2049-2051.
Peer reviewed (verified by ORBi)
This letter presents an on-chip common-mode cancelation circuit (CMCC), which increases the immunity to electromagnetic interference (EMI) of the input stage in a classic CMOS operational amplifier. Two test ...
Wu, T., Arefin, M. S., Redouté, J.-M., & Yuce, M. R. (2017). Flexible wearable sensor nodes with solar energy harvesting. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 3273-3276.
Peer reviewed
Wearable sensor nodes have gained a lot of attention during the past few years as they can monitor and record people's physical parameters in real time. Wearable sensor nodes can promote healthy lifestyles and ...
Wu, T., Wu, F., Redouté, J.-M., & Yuce, M. R. (2017). An Autonomous Wireless Body Area Network Implementation Towards IoT Connected Healthcare Applications. IEEE Access, 5, 11413-11422.
Peer reviewed (verified by ORBi)
Internet of Things (IoT) is a new technological paradigm that can connect things from various fields through the Internet. For the IoT connected healthcare applications, the wireless body area network (WBAN ...
Alsunaydih, F. N., Redouté, J.-M., & Yuce, M. R. (2016). Improving resolution of robotic capsule locomotion using dynamic electromagnetic field. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2016-October, 219-222.
Peer reviewed
This paper describes a new method to control the motion of swallowable wireless capsule endoscopy devices. A dynamic magnetic field produced by a set of external magnetic coils is used to manage the locomotion ...
Arefin, M. S., Redouté, J.-M., & Yuce, M. R. (2016). A Low-Power and Wide-Range MEMS Capacitive Sensors Interface IC Using Pulse-Width Modulation for Biomedical Applications. IEEE Sensors Journal, 16(17), 6745-6754.
Peer reviewed
This paper presents a low power, compact, and low-complexity pulse-width modulation-based interface circuit for capacitive MEMS sensors. The circuit is designed using a ring oscillator, an RC controlled pulse ...
Arefin, M. S., Redouté, J.-M., & Yuce, M. R. (2016). Meandered conformai antenna for ISM-band ingestible capsule communication systems. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2016-October, 3031-3034.
Peer reviewed
The wireless capsule has been used to measure physiological parameters in the gastrointestinal tract where communication from in-body to external receiver is necessary using a miniaturized antenna with high ...
Arefin, M. S., Redouté, J.-M., & Yuce, M. R. (2016). A MEMS Interface IC with Low-Power and Wide-Range Frequency-to-Voltage Converter for Biomedical Applications. IEEE Transactions on Biomedical Circuits and Systems, 10(2), 455-466.
Peer reviewed (verified by ORBi)
This paper presents an interface circuit for capacitive and inductive MEMS biosensors using an oscillator and a charge pump based frequency-to-voltage converter. Frequency modulation using a differential ...
Bhatt, D., Mukherjee, J., & Redouté, J.-M. (2016). A high-isolation linear folded mixer for ISM band in UMC 180NM CMOS technology. Microwave and Optical Technology Letters, 58(10), 2461-2466.
Peer reviewed (verified by ORBi)
This paper presents an integrated radio frequency (RF) downconversion folded mixer that operates in the 2.4 GHz industrial, scientific, and medical (ISM) band by using UMC 180 nm RF CMOS. It is implemented by ...
Bhatt, D., Mukherjee, J., & Redouté, J.-M. (2016). Low-Power Linear Bulk-Injection Mixer for Wide-Band Applications. IEEE Microwave and Wireless Components Letters, 26(10), 828-830.
Peer reviewed (verified by ORBi)
A novel high third-order intermodulation product (IIP3), low-power, inverter-based bulk-injection mixer design is presented in this letter. The architecture of the proposed mixer consists of four complementary ...
Boyapati, S., Redouté, J.-M., & Baghini, M. S. (2016). A highly EMI-immune folded cascode OpAmp in 0.18 μm CMOS technology. IEEE International Symposium on Electromagnetic Compatibility, 2016-November, 546-551.
Peer reviewed
This paper describes a folded cascode CMOS instrumentation amplifier input stage, which has an increased immunity to electromagnetic interference (EMI). The proposed structure uses a source-buffered concept ...
Boyapati, S., Redouté, J.-M., & Baghini, M. S. (2016). Modeling and design of EMI-immune OpAmps in 0.18-μm CMOS Technology. IEEE Transactions on Electromagnetic Compatibility, 58(5), 1609-1616.
Peer reviewed (verified by ORBi)
This paper explores the modeling and design of Miller-based operational amplifier structures that are highly immune to electromagnetic interference (EMI). The proposed CMOS Miller-based operational amplifier ...
Coccoli, A., Richelli, A., & Redouté, J.-M. (2016). EMI susceptibility of a digitally based analog amplifier in a 180-nm CMOS process. IEEE Transactions on Electromagnetic Compatibility, 58(4), 1236-1239.
Peer reviewed (verified by ORBi)
This paper investigates and reports the susceptibility to electromagnetic interference (EMI) of a digitally based analog amplifier. The amplifier has been designed in the UMC 180-nm CMOS technology with ...
Eslampanah, R., Ahmed, S., Williamson, M., Redouté, J.-M., & Faulkner, M. (2016). Adaptive duplexing for transceivers supporting aggregated transmissions. IEEE Transactions on Vehicular Technology, 65(9), 6842-6852.
Peer reviewed (verified by ORBi)
Wireless systems employing frequency-division duplexing (FDD) must use duplexing filters to isolate the sensitive receiver from its own strong transmission. The number of filters in the duplexer is equal to ...
Laurenson, C., Rivet, F., Yuce, M. R., & Redouté, J.-M. (2016). A 180 nm CMOS analog adaptive sampler for blood pressure feature extraction. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2016-October, 4841-4844.
Peer reviewed
This paper presents an analogue feature detector for extraction and sampling of key-points on an arterial blood pressure signal in both humans and small mammals used as human physiological models. A CMOS ...
Matig-A, G. A., Yuce, M. R., & Redouté, J.-M. (2016). An Integrated LVDS Transmitter-Receiver System with Increased Self-Immunity to EMI in 0.18-μm CMOS. IEEE Transactions on Electromagnetic Compatibility, 58(1), 231-240.
Peer reviewed (verified by ORBi)
This paper presents the design of an integrated low-voltage differential signaling (LVDS) transmitter-receiver system with a superior immunity to electromagnetic interference (EMI). The effects of injected RF ...
Matig-A, G., Yuce, M. R., & Redouté, J.-M. (2016). EMI susceptibility of high speed differential wireline communication front-ends. IEEE International Symposium on Electromagnetic Compatibility, 2016-November, 382-387.
Peer reviewed
This paper presents an in-depth electromagnetic susceptibility (EMS) analysis for three commonly used differential high speed wireline interfaces, namely: low voltage differential signaling (LVDS), current ...
Richelli, A., Delaini, G., Grassi, M., & Redouté, J.-M. (2016). Susceptibility of Operational Amplifiers to Conducted EMI Injected Through the Ground Plane into Their Output Terminal. IEEE Transactions on Reliability, 65(3), 1369-1379.
Peer reviewed (verified by ORBi)
In practical printed circuit board (PCB) designs, electromagnetic interference (EMI) is coupled from the ground plane, which is commonly shared among the analog, digital, and mixed-signal integrated circuits ...
Richelli, A., Grassi, M., & Redouté, J.-M. (2016). Design of an integrated tunable differential negative resistance in UMC 0.18 μm. Microelectronics Journal, 48, 1-6.
Peer reviewed (verified by ORBi)
This paper presents a CMOS floating tunable differential resistance, which has the property of being positive with respect to common-mode signals while being negative for differential signals. The designed ...
Wu, T., Arefin, M. S., Redouté, J.-M., & Yuce, M. R. (2016). A solar energy harvester with an improved MPPT circuit for wearable IoT applications. Proceedings.
Peer reviewed
One of the main issues of wearable IoT devices is the limited battery technology. Energy harvesting will be a key development for health and fitness oriented wearable devices that can measure signals ...
Wu, T., Arefin, M. S., Shmilovitz, D., Redouté, J.-M., & Yuce, M. R. (2016). A flexible and wearable energy harvester with an efficient and fast-converging analog MPPT. IEEE Biomedical Circuits and Systems Conference Proceedings, BioCAS, 336-339.
Peer reviewed
This paper presents a flexible energy harvesting system with an analog maximum power point tracking (MPPT) algorithm that operates using the output current. The proposed MPPT circuit is simplified as only one ...
Aldaoud, A., Laurenson, C., Rivet, F., Yuce, M. R., & Redouté, J.-M. (2015). Design of a miniaturized wireless blood pressure sensing interface using capacitive coupling. IEEE/ASME Transactions on Mechatronics, 20(1), 487-491.
Peer reviewed (verified by ORBi)
This paper presents the implementation of a miniaturized wireless blood pressure sensor interface. The system uses capacitive coupling in order to transmit the data, as well as wireless inductive powering ...
Arefin, M. S., Redouté, J.-M., & Yuce, M. R. (2015). Frequency modulation based resistive sensing for wearable galvanic skin response. Proceedings.
Peer reviewed
This paper presents a frequency modulation based readout circuit for the measurement of skin conductance or resistance. A charge pump based frequency-to-voltage converter circuit with adjustable sensitivity is ...
Buxi, D., Redouté, J.-M., & Yuce, M. R. (2015). Cuffless blood pressure estimation from the carotid pulse arrival time using continuous wave radar. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2015-November, 5704-5707.
Peer reviewed
Ambulatory blood pressure monitors based on pulse transit time are limited by the challenge of changing vascular tone. This study focuses on the use of the carotid artery as an alternative location for ...
Buxi, D., Redouté, J.-M., & Yuce, M. R. (2015). A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time. Physiological Measurement, 36(3), 1-R26.
Peer reviewed (verified by ORBi)
Blood pressure monitoring based on pulse transit or arrival time has been the focus of much research in order to design ambulatory blood pressure monitors. The accuracy of these monitors is limited by several ...
Grassi, M., Redouté, J.-M., & Richelli, A. (2015). Increased EMI immunity in CMOS operational amplifiers using an integrated common-mode cancellation circuit. IEEE International Symposium on Electromagnetic Compatibility, 2015-Septmber, 34-39.
Peer reviewed
This paper presents an on-chip common-mode cancellation circuit which increases the immunity to electromagnetic interference (EMI) of integrated CMOS operational amplifiers when EMI is injected into their ...
Kennedy, S., Yuce, M. R., & Redouté, J.-M. (2015). An evaluation and comparison of conducted emission test methods for Integrated Circuits. Conference Proceedings - GEMCCON 2015: IEEE Global Electromagnetic Compatibility Conference.
Peer reviewed
This paper presents a comparison of conducted emission test measurements. Traditional Line Impedance Stabilisation Network (LISN) conducted emission methods are compared with Integrated Circuits (IC) test ...
Laurenson, C., Rivet, F., Yuce, M. R., & Redouté, J.-M. (2015). A 1.04μW wireless integrated MEMS interface in UMC 0.18μm CMOS. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2015-November, 889-892.
Peer reviewed
This paper presents an ultra low-power integrated interface for capacitive and resistive MEMS and sensors, intended for use in biomedical applications. The interface encodes the sensed data in the time between ...
Matig-a, G. A., Yuce, M. R., & Redouté, J.-M. (2015). An integrated LVDS transmitter in 0.18-μm CMOS technology with high immunity to EMI. IEEE Transactions on Electromagnetic Compatibility, 57(1), 128-134.
Peer reviewed (verified by ORBi)
This paper presents an on-chip design topology that compensates the effects of electromagnetic interference (EMI) in a low-voltage differential signaling (LVDS) transmitter. The proposed structure enables the ...
Mohammadi, A., Redouté, J.-M., & Yuce, M. R. (2015). Low-threshold CMOS rectifier design for energy harvesting in biomedical sensors. Proceedings.
Peer reviewed
The power transfer efficiency of energy harvesting systems is strongly dependent on the power conditioning circuits, especially rectifiers. The voltage drop across rectifier and its leakage current can ...
Mohammadi, A., Redouté, J.-M., & Yuce, M. R. (2015). Wireless power transmission for biomedical implants: The role of near-zero threshold CMOS rectifiers. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2015-November, 5453-5456.
Peer reviewed
Biomedical implants require an electronic power conditioning circuitry to provide a stable electrical power supply. The efficiency of wireless power transmission is strongly dependent on the power conditioning ...
Morrison, D., Ablitt, T., & Redouté, J.-M. (2015). Miniaturized Low-Power Wireless Sensor Interface. IEEE Sensors Journal, 15(9), 4731-4732.
Peer reviewed (verified by ORBi)
This letter presents a low-power miniaturized wireless sensor module, which can be reconfigured to interface with a variety of sensors as well as function as a receiver node. Measurements confirm that this ...
Redouté, J.-M., & Richelli, A. (2015). A methodological approach to EMI resistant analog integrated circuit design. IEEE Electromagnetic Compatibility Magazine, 4(2), 92-100.
Peer reviewed (verified by ORBi)
This paper describes the effect of EMI (electromagnetic interference) on analog integrated circuits, and introduces four design guidelines targeted at improving the susceptibility of analog integrated circuits ...
Richelli, A., Matig-A, G., & Redouté, J.-M. (2015). Design of a folded cascode opamp with increased immunity to conducted electromagnetic interference in 0.18 μm CMOS. Microelectronics Reliability, 55(3-4), 654-661.
Peer reviewed (verified by ORBi)
This paper presents a folded cascode CMOS instrumentation amplifier input stage with an increased immunity to electromagnetic interference (EMI): this structure is based on a recycling folded cascode topology ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2015). Propagation, Power Absorption, and Temperature Analysis of UWB Wireless Capsule Endoscopy Devices Operating in the Human Body. IEEE Transactions on Microwave Theory and Techniques, 63(11), 3823-3833.
Peer reviewed (verified by ORBi)
With the increasing use of wireless capsule endoscopy (WCE) devices in healthcare, it is of utmost importance to analyze the electromagnetic power absorption and thermal effects caused by in-body propagation ...
Al-Kalbani, A. I., Yuce, M. R., & Redouté, J.-M. (2014). A biosafety comparison between capacitive and inductive coupling in biomedical implants. IEEE Antennas and Wireless Propagation Letters, 13, 1168-1171.
Peer reviewed (verified by ORBi)
This letter investigates the link efficiencies and ensuing biohazards when capacitive versus inductive coupling is used to power biomedical implants electromagnetically. Electromagnetic simulations illustrate ...
Al-Kalbani, A., Yuce, M. R., & Redouté, J.-M. (2014). Electromagnetic interference in brain implants using multiple coils: Biosafety and data communication performance. IEEE Transactions on Electromagnetic Compatibility, 56(2), 490-493.
Peer reviewed (verified by ORBi)
This letter investigates the use of multiple coils for the powering of and the data communication to brain implants. It studies the limits imposed by these coils in terms of biosafety and interference in the ...
Amirkhanzadeh, R., Sjöland, H., Redouté, J.-M., Nobbe, D., & Faulkner, M. (2014). High-resolution passive phase shifters for adaptive duplexing applications in SOS process. IEEE Transactions on Microwave Theory and Techniques, 62(8), 1678-1685.
Peer reviewed (verified by ORBi)
Two high-resolution passive delay line phase shifters in silicon-on-sapphire are compared. Both make use of digitally tuned capacitor loaded π sections to obtain 360° phase control. The first has a nominal ...
Amirkhanzadeh, R., Sjoland, H., Redouté, J.-M., Nobbe, D., & Faulkner, M. (2014). L-band 180° passive phase shifter employing auto-transformer in an SOS process. IEEE International Symposium on Circuits and Systems Proceedings, 333-336.
Peer reviewed
In this paper, we present a new topology to implement a passive 180° phase shifter using on-chip auto-transformer in an SOS process. The measured results indicate a phase variation of less than 2° over the ...
Arefin, M. S., Bulut Coskun, M., Alan, T., Redouté, J.-M., Neild, A., & Rasit Yuce, M. (2014). A microfabricated fringing field capacitive pH sensor with an integrated readout circuit. Applied Physics Letters, 104(22).
Peer reviewed (verified by ORBi)
This work presents a microfabricated fringe-field capacitive pH sensor using interdigitated electrodes and an integrated modulation-based readout circuit. The changes in capacitance of the sensor result from ...
Arefin, M. S., Coskun, M. B., Alan, T., Neild, A., Redouté, J.-M., Yuce, M. R., & Arregui, F. J. (2014). A MEMS capacitive pH sensor for high acidic and basic solutions. Proceedings of IEEE Sensors, 2014-December(December), 1792-1794.
Peer reviewed (verified by ORBi)
We have developed a micro-scale chip-based pH sensing system, which can effectively measure the changes in pH ranging from 1 to 4 and 10 to 12. This method relies on fringing field capacitive measurements. A ...
Bhatt, D., Mukherjee, J., & Redouté, J.-M. (2014). A high isolation linear folded mixer for WiFi applications. IEEE International Symposium on Circuits and Systems Proceedings, 694-697.
Peer reviewed
A 2.4GHz novel RF Mixer with folded structure designed in 180nm RF-Mixed signal technology has been investigated. It is implemented by using double balanced transconductance switch (GmSw) configuration. The ...
Buxi, D., Redouté, J.-M., & Yuce, M. R. (2014). Frequency sensing of medical signals using low-voltage piezoelectric sensors. Sensors and Actuators. A, Physical, 220, 373-381.
Peer reviewed (verified by ORBi)
Piezoelectric sensors are used to pick up low level vibrations in automotive, biomedical and industrial fields and are subject to errors due to the input current and voltage noise of amplifiers, when connected ...
Buxi, D., Redouté, J.-M., & Yuce, M. R. (2014). A frequency-sensing readout using piezoelectric sensors for sensing of physiological signals. Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC, 1420-1423.
Peer reviewed
Together with a charge or voltage amplifier, piezoelectric sensors are commonly used to pick up physiological vibrations from the body. As an alternative to chopper or auto-zero amplifiers, frequency sensing ...
Eslampanah, R., Linton, L., Ahmed, S., Amirkhanzadeh, R., Pourakbar, M., Redouté, J.-M., & Faulkner, M. (2014). Active duplexing for software defined radio. IEEE International Symposium on Circuits and Systems Proceedings, 185-188.
Peer reviewed
Passive filters are implemented via advanced technologies in the form of surface acoustic wave (SAW) and thin film bulk acoustic resonator (FBAR) devices. These not only exhibit low noise and high linearity ...
Eslampanah, R., Pourakbar, M., Ahmed, S., Redouté, J.-M., & Faulkner, M. (2014). RF modulator design for a low level pilot sub-system. Australian Microwave Symposium, Conference Proceedings, 25-26.
Peer reviewed
This paper presents an adaptive duplexer using cancelling instead of filtering to obtain sufficient transmitter (Tx) leakage and noise isolation in the receiver. A low level pseudo-noise (PN) pilot signal is ...
Matig-A, G., Yuce, M. R., & Redouté, J.-M. (2014). An EMI resistant integrated LVDS transmitter in 0.18μm CMOS. IEEE International Symposium on Electromagnetic Compatibility, 692-697.
Peer reviewed
In this paper, an on-chip method of compensating the effects of electromagnetic interference (EMI) on a low voltage differential signaling (LVDS) transmitter is presented. The proposed structure provides a ...
Richelli, A., & Redouté, J.-M. (2014). Increasing the EMI immunity of CMOS operational amplifiers using an on-chip common-mode cancellation circuit. IEEE International Symposium on Electromagnetic Compatibility, 698-702.
Peer reviewed
This paper presents an on-chip common-mode cancellation circuit which increases the common-mode rejection ratio (CMRR) in operational amplifiers, while at the same time increasing their immunity to ...
Subrahmanyam, B., Das, D., Baghini, M. S., & Redouté, J.-M. (2014). A balanced CMOS OpAmp with high EMI immunity. IEEE International Symposium on Electromagnetic Compatibility, 703-708.
Peer reviewed
In this paper a balanced CMOS operational amplifier which has higher electromagnetic interference (EMI) immunity compared to a double differential amplifier and standard Miller operational amplifier, has been ...
Thotahewa, K. M. S., Al-Kalbani, A. I., Redouté, J.-M., & Yuce, M. R. (2014). Electromagnetic effects of wireless transmission for neural implants. Neural Computation, Neural Devices, and Neural Prosthesis (pp. 1-22). Springer New York.
Peer reviewed
With the extensive use of wireless devices within or at close proximity to the human body, electromagnetic effects caused by the interaction between radio frequency waves and human tissues should be considered ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2014). Hardware implementation of an IR-UWB coordinator node for WBAN applications. IEEE International Symposium on Personal, Indoor and Mobile Radio Communications, PIMRC, 2014-June, 2168-2172.
Peer reviewed
IR-UWB communication systems have become popular for Wireless Body Area Network (WBAN) applications in recent times. This paper presents the development and testing of an IR-UWB coordinator node that includes ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2014). Implementation of Ultra-Wideband (UWB) sensor nodes for WBAN applications. Ultra-Wideband and 60 GHz Communications for Biomedical Applications. Springer US.
Peer reviewed
Wireless body area networks (WBAN) applications benefit extensively from the advantages offered by the unique features of ultra-wideband (UWB) wireless communication. This chapter focuses on the hardware ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2014). A low-power wearable dual-band wireless body area network system: Development and experimental evaluation. IEEE Transactions on Microwave Theory and Techniques, 62(11), 2802-2811.
Peer reviewed (verified by ORBi)
Wireless body area network (WBAN) applications benefit extensively from the advantages offered by unique features of ultra-wideband (UWB) wireless communication, such as high data rate, low power consumption ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2014). Medium Access Control (MAC) Protocols for Ultra-Wideband (UWB)-Based Wireless Body Area Networks (WBAN). Ultra-Wideband and 60 GHz Communications for Biomedical Applications (pp. 131-152). Springer US.
Peer reviewed
A wireless body area network (WBAN) is a dedicated network developed to operate in, on or near the human body. In order to design a power-efficient WBAN, a cross-layer solution is required. The physical layer ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2014). Ultra Wideband Wireless Body Area Networks. Springer International Publishing.
This book explores the design of ultra wideband (UWB) technology for wireless body-area networks (WBAN). The authors describe a novel implementation of WBAN sensor nodes that use UWB for data transmission and ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2014). A UWB wireless capsule endoscopy device. Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC, 6977-6980.
Peer reviewed
Wireless capsule endoscopy (WCE) presents many advantages over traditional wired endoscopic methods. The performance of WCE devices can be improved using high-frequency communication systems such as Impulse ...
Thotahewa, K., Redouté, J.-M., & Yuce, M. R. (2014). On medical implant communication of IR-UWB. Proceedings (pp. 26-31). ICST.
Peer reviewed
Impulse Radio-Ultra-Wideband (IR-UWB) is gaining popularity for a variety of short-range Wireless Body Area Network (WBAN) applications. In-body to outside-body communication is one of the possible ...
Aiello, O., & Redouté, J.-M. (2013). Design of a neural recording amplifier robust to EMI. 2013 Asia-Pacific Symposium on Electromagnetic Compatibility, APEMC 2013.
Peer reviewed
This paper deals with power line interference during the recording of biopotential signals. A scheme to improve biopotential signal acquisition as well as a new fully-differential self-biased neural recording ...
Al-Kalbani, A. I., Yuce, M. R., & Redouté, J.-M. (2013). Design methodology for maximum power transmission, optimal BER-SNR and data rate in biomedical implants. IEEE Communications Letters, 17(10), 1897-1900.
Peer reviewed (verified by ORBi)
Using Pulse-Width Modulation Amplitude-Shift Keying (PWM-ASK) in biomedical implants enables the simultaneous transmission of wireless energy as well as data using a single inductive link. This paper ...
Redouté, J.-M., Browne, D., Fitrio, D., Lowery, A., & Kleeman, L. (2013). A reduced data bandwidth integrated electrode driver for visual intracortical neural stimulation in 0.35 μm high voltage CMOS. Microelectronics Journal, 44(4), 277-282.
Peer reviewed (verified by ORBi)
This paper presents an integrated electrode driver for intracortical neural stimulation requiring a reduced data bandwidth. The device has been fabricated in the OnSemi I3T50 0.35μm high voltage CMOS process ...
Redouté, J.-M., & Richelli, A. (2013). A fundamental approach to EMI resistant folded cascode operational amplifier design. IEEE International Symposium on Electromagnetic Compatibility, 203-208.
Peer reviewed
This paper introduces four design guidelines targeted at improving the susceptibility of circuits to electromagnetic interference (EMI), and applies these to the practical design of folded cascode operational ...
Sadeghi, H., Lai, D. T. H., Redouté, J.-M., & Zayegh, A. (2013). Classic and quantum capacitances in bernal bilayer and trilayer graphene field effect transistor. Journal of Nanomaterials, 2013.
Peer reviewed (verified by ORBi)
Our focus in this study is on characterizing the capacitance voltage (C-V) behavior of Bernal stacking bilayer graphene (BG) and trilayer graphene (TG) as the channel of FET devices. The analytical models of ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2013). Electromagnetic and thermal effects of IR-UWB wireless implant systems on the human head. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 5179-5182.
Peer reviewed
The usage of implanted wireless transmitting devices inside the human body has become widely popular in recent years. Applications such as multi-channel neural recording systems require high data rates in the ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2013). Electromagnetic power absorption of the human abdomen from IR-UWB based wireless capsule endoscopy devices. Proceedings of the 2013 IEEE International Conference on Ultra-Wideband, ICUWB 2013 (pp. 79-84).
Peer reviewed
Impulse Radio-Ultra Wide Band (IR-UWB) can be used to enhance the performance of Wireless Capsule Endoscopy (WCE) Devices due to its high data rate capability, low power consumption and small form factor. This ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2013). Implementation of a dual band body sensor node. Proceedings of the 2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Tecbhnologies for Biomedical and Healthcare Applications, IMWS-BIO 2013. IEEE Computer Society.
Peer reviewed
Ultra Wide Band (UWB) can be considered as a lucrative wireless technology for Wireless Body Area Network (WBAN) applications that demand for power stringent operation, high data rate and low form factor. The ...
Thotahewa, K. M. S., Redouté, J.-M., & Yuce, M. R. (2013). SAR, SA, and temperature variation in the human head caused by IR-UWB implants operating at 4 GHz. IEEE Transactions on Microwave Theory and Techniques, 61(5), 2161-2169.
Peer reviewed (verified by ORBi)
With the extensive use of wireless devices within or at close proximity to the human body, electromagnetic effects caused by the interaction between RF waves and human tissues need to be considered with ...
Al-Kalbani, A. I., Yuce, M. R., & Redouté, J.-M. (2012). Performance of a biomedical implant communication system using PWM coded ASK. International Symposium on Communications and Information Technologies, ISCIT, 133-138.
Peer reviewed
Biomedical implanted systems require wireless technology to transfer data and power to the implanted devices. This paper compares the performance and suitability of the ASK, FSK, PSK, OOK and PWM-ASK ...
Al-Kalbani, A. I., Yuce, M. R., & Redouté, J.-M. (2012). Safe SAR levels in inductively powered brain implanted visual prostheses. IEEE International Symposium on Electromagnetic Compatibility.
Peer reviewed
This paper derives the health risks of an inductively powered brain implanted visual prosthesis with a CAD based head model. A high efficiency self-oscillating class E transmitter circuit operating at 5 MHz ...
Al-Kalbani, A., Yuce, M. R., & Redouté, J.-M. (2012). Specific absorption rate of inductively powered brain implanted circuits. Asia-Pacific Symposium on Electromagnetic Compatibility, APEMC, 457-460.
Peer reviewed
This paper discusses the simulated exposure to a 5 MHz electromagnetic field powering implanted electronic devices using an inductive link. A high efficiency class-E transmitter circuit operating at 5 MHz has ...
Yuce, M. R., Redouté, J.-M., Thotahewa, K. M., & Keong, H. C. (2012). Development of low-power UWB body sensors. International Symposium on Communications and Information Technologies, ISCIT, 143-148.
Peer reviewed
Ultra-wide band (UWB) is gaining popularity as a physical layer technique for low power and high data rate wireless applications. Currently most wireless body area network (WBAN) platforms are based on ...
Pourakbar, M., Redouté, J.-M., & Faulkner, M. (2011). Design and implementation of high power, high linearity stacked RF FET switches in a 250 nm silicon on sapphire process. Asia-Pacific Microwave Conference Proceedings, APMC, 299-302.
Peer reviewed
The RF circuitry in new generation mobile handsets is continuously becoming smaller while containing more functionality. Silicon-on-sapphire (SOS) technology is an advanced active device process that eases the ...
Redouté, J.-M. (2011). EMI insensitive reference current generation and distribution in an 8 bit current steering D/A converter in UMC 0.18 μm CMOS. Asia-Pacific Microwave Conference Proceedings, APMC, 287-290.
Peer reviewed
This paper describes the electromagnetic susceptibility of an 8 bit current steered thermometer encoded digital to analog converter (DAC) when electromagnetic interference (EMI) is injected into its bias ...
Redouté, J.-M., & Steyaert, M. (2010). Kuijk bandgap voltage reference with high immunity to EMI. IEEE Transactions on Circuits and Systems. Part II, Express Briefs, 57(2), 75-79.
Peer reviewed (verified by ORBi)
This brief evaluates the effect of conducted electromagnetic interference (EMI) that is injected in the power supply of a classic Kuijk bandgap reference voltage circuit. Two modified Kuijk bandgap topologies ...
Redouté, J.-M., & Steyaert, M. S. J. (2010). EMI-resistant CMOS differential input stages. IEEE Transactions on Circuits and Systems I: Regular Papers, 57(2), 323-331.
Peer reviewed (verified by ORBi)
This paper studies and compares the performances of CMOS differential input stages with a high degree of immunity against electromagnetic interferences (EMIs) and introduces a source-buffered differential pair ...
Van Breussegem, T., Wens, M., Redouté, J.-M., Geukens, E., Geys, D., & Steyaert, M. (2009). A DMOS integrated 320mW capacitive 12V to 70V DC/DC-converter for LIDAR applications. IEEE Energy Conversion Congress and Exposition, ECCE, 3865-3869.
Peer reviewed
A 320mW integrated switched capacitor DC-DC converter is realized in a 0.35μm DMOS high voltage technology. This 10 stage converter generates 70V from a 12V voltage supply, at a maximum efficiency of 85.5% per ...
Wens, M., Redouté, J.-M., Blanchaert, T., Bleyaert, N., & Steyaert, M. (2009). An integrated 10A, 2.2ns rise-time laser-diode driver for LIDAR applications. European Solid-State Circuits Conference Proceedings, ESSCIRC, 144-147.
Peer reviewed
An integrated laser-diode driver for LIDAR applications in a 0.35 μm 80 V CMOS technology is realized. The integration of the power switch as a n-DMOS allows a peak current of 10 A, with a corresponding rise ...
Redouté, J.-M., & Steyaert, M. (2008). Active load for differential amplifier with high output impedance and reduced supply voltage. Electronics Letters, 44(2), 67-68.
Peer reviewed (verified by ORBi)
An active load which uses positive feedback to achieve an impedance transformation is introduced. The use of this circuit as an active load for a differential amplifier is explored, and it is illustrated with ...
Redouté, J.-M., & Steyaert, M. (2008). A cmos source-buffered differential input stage with high EMI suppression. European Solid-State Circuits Conference Proceedings, ESSCIRC, 318-321.
Peer reviewed
This paper introduces a CMOS source-buffered differential input stage exhibiting a high degree of immunity against electromagnetic interferences (EMI) which are applied on its input pins. The measurements of a ...
Redouté, J.-M., & Steyaert, M. (2008). EMI resisting smart-power integrated LIN driver with reduced slope pumping. Proceedings of the Custom Integrated Circuits Conference, 643-646.
Peer reviewed
This paper presents the design of a Local Interconnect Network (LIN) smart-power driver exhibiting a high degree of immunity against electromagnetic interference (EMI). Improving previous designed ...
Redouté, J.-M., & Steyaert, M. (2008). An instrumentation amplifier input circuit with a high immunity to EMI. IEEE International Symposium on Electromagnetic Compatibility.
Peer reviewed
This paper presents an instrumentation amplifier input circuit exhibiting a high degree of immunity against conducted common-mode electromagnetic interferences (EMI) which are injected into its inputs. The ...
Redouté, J.-M., Walravens, C., Van Winckel, S., & Steyaert, M. S. J. (2008). An externally trimmed integrated DC current regulator insensitive to conducted EMI. IEEE Transactions on Electromagnetic Compatibility, 50(1), 63-70.
Peer reviewed (verified by ORBi)
This paper introduces a new integrated dc current regulator using external resistive trimming, which presents a high degree of immunity against conducted electromagnetic interference (EMI). While classic ...
Redouté, J.-M., & Steyaert, M. (2007). An EMI resisting LIN driver in 0.35-micron high-voltage CMOS. IEEE Journal of Solid-State Circuits, 42(7), 1574-1582.
Peer reviewed (verified by ORBi)
This paper describes the design of a Local Interconnect Network (LIN) integrated output driver circuit exhibiting a high degree of immunity against conducted electromagnetic interference (EMI). The transmitted ...
Redouté, J.-M., & Steyaert, M. (2007). Measurement of EMI induced input offset voltage of an operational amplifier. Electronics Letters, 43(20), 1088-1090.
Peer reviewed (verified by ORBi)
An efficient measurement technique is introduced for determining the input referred offset voltage induced by electromagnetic interference (EMI) in operational amplifiers. © The Institution of Engineering and Technology 2007.
Redouté, J.-M., Walravens, C., Van Winckel, S., & Steyaert, M. (2007). An integrated DC current regulator with high EMI suppression. ESSCIRC 2007 - Proceedings of the 33rd European Solid-State Circuits Conference, 420-423.
Peer reviewed
This paper presents an integrated DC current regulator using resistive trimming, which provides a high degree of immunity against conducted electromagnetic interference (EMI). While classic topologies generate ...
Walravens, C., Van Winckel, S., Redouté, J.-M., & Steyaert, M. (2007). Efficient reduction of electromagnetic interference effects in operational amplifiers. Electronics Letters, 43(2), 84-85.
Peer reviewed (verified by ORBi)
When subjected to electromagnetic interference, an operational amplifier will generate a DC offset. A thorough comparison between two approaches to reduce this offset is presented. Through mathematical ...
Redouté, J.-M., & Steyaert, M. (2006). EMI resisting CMOS differential pair structure. Electronics Letters, 42(21), 1217-1218.
Peer reviewed (verified by ORBi)
An improved differential pair structure, which is highly immune to conducted electromagnetic interference (EMI), is described. This new structure has a very low input offset voltage, even when a large EMI is ...
Redouté, J.-M., & Steyaert, M. (2006). An EMI resisting LIN driver. IEEE ESSCIRC Proceedings.
Peer reviewed
This paper describes the design of a LIN driver structure, which offers a high degree of immunity against conducted electromagnetic interference (EMI): this circuit withstands the highest levels of the "direct ...
Redouté, J.-M., & Steyaert, M. (2006). Improved EMI filtering current mirror structure requiring reduced capacitance. Electronics Letters, 42(10), 560-561.
Peer reviewed (verified by ORBi)
The design of an improved current mirror is described, capable of filtering conducted electromagnetic interference without causing charge pumping. One of the major advantages of this structure lies in the ...
Redouté, J.-M., & Steyaert, M. (2005). Current mirror structure insensitive to conducted EMI. Electronics Letters, 41(21), 1145-1146.
Peer reviewed (verified by ORBi)
A novel and integrable current mirror structure insensitive to the common charge pumping phenomenon, typically occasioned by conducted electromagnetic interference (EMI), is presented. © IEE 2005.